DT MINI –SINSIL
Absorbance 200 – 1100nm D2&W Integrated Shutter
Light SourcesContact Us for Inquiry
Absorbance 200 – 1100nm D2&W Integrated Shutter
Light SourcesContact Us for Inquiry
Absorption / Reflection / Transmission/PL High sensitivity Back-thinned CCD image sensor, High resolution,2048sensors, 200-1100nm Res. 1nm, Replaceable Slits, 6ms to 10s On board memory 5000 spectra Signal to nms 400:1 Stray light >3AU, Dynamic Range 1200

Range :200-850nm, 350-1100nm, 200-1025nm Resolution -1.3/2nm, Integration for 10µs to 10s, High-sensitivity CMOS detector, On board memory 50,000 spectra, 4500scans/s SN ratio 290:1 USB/Ethernet

Absorption / Reflection /PL/ Transmission/Raman High sensitivity, 22e-/count TE cooled to -25 0 C, 200-1100nm 1024 x 58 Pixels, Bach thinned Dynamic range 85000:1 On board memory 15000spectra signal-to-noise ratio >1000:1

competitively price Wavelength 200-1100nm Range 200-850nm, 350-1000nm, 220-1025nm Integration time: 1µs to 2s, USB type C Small optical bunch 88x63x318nm Replaceable slit, 3648 sensors, 8x 200um

220-1100nm, resolution: /nm 8x200um/3648 OR 14nm x200nm 14s -2 s measurement time Large optical bench 148x106x182nm

Spectrometer – Absorbance Menatation OEM, Low resolution, Volume Pricing choose 400nm in 200-1100nm

900-1700nm, 900-2100nm, 900-2500nm Detectors 256 or 512 Resolution 5-10nm TE coolded

Absorption / Reflection / Transmission Wavelength Range: 210nm – 2.5μm Source: Deuterium & Tungsten Halogen

Reflection / Absorption / Transmission 360-2000nm,20Watts, Shutte,r Attanuator

Radiometrically Calibrated Light Source Wavelength Range: 210nm – 1.1μm Source: Deuterium & Tungsten Halogen

Radiometric Calibration 300 – 1050nm 6.5W

Wavelength calibration 253-900nm

300W Xe Lamp PL 300W Lamp/ Power display 200-850nm Monochrometer

10mm path Absorption/PL Product: SQUARE ONE Cuvette Holder Collimating Lenses: Three 74-UV fused silica lenses (200-2000 nm) Filter Slot Specification: Two slots in total. Each slot accepts

10mm path Product: CUV-UV Cuvette Holders Collimating Lenses: Two 74-UV f/2 fused silica lenses (200-2000 nm) Filter Slot Specification: Accepts filters up to 6.35 mm (1/4") thickness Integrated Light Source: No Pathlength: 1 cm

10mm path 90%/PL Product: CUV-FL-DA Collimating Lenses: One of 74-UV fused silica lens (200-2000 m) Filter Slot Specification: Accepts filters up to 6.35 mm (1/4") thickness

Product: STAGE-RTL-T Reflection-Transmission Stage Base Dimensions: 206.3 mm diameter Rail Height: Adjustable to 400 mm Sample Area Dimensions: 152.4 mm diameter

10mm path Cell Material: Ultem Internal Volume: 26 µL Pathlength: 10 mm Wavelength Range: 210nm – 2μm Window Material: Fused silica

100mm path Flow cell SMA for optical fiber Absorbance

Product:R200-7-UV-VIS Wavelength Range: 300nm – 1.1μm Fiber Core Size: 200 µm Length: 2 m Jacket: PVDF zip tube Probe Ferrule Diameter: 6.35 mm (1/4″) Solarization Resistant Reflection/Backscatter Probe

Product: TP300-UV-VIS Wavelength Range: 200nm – 1.1μm Fiber Core Size: 300 µm Length: 2 m Jacket: PVDF zip tube Probe Ferrule Diameter: Internal stainless steel probe assembly: 3.175 mm (1/8″) and PEEK polymer sleeve: 6.35 mm (1/4″) Harsh Environment Transmission Dip Probe

Product: QBIF200-MIXED Wavelength Range: 300nm – 2.1μm Fiber Core Size: 200 µm Length: 2 m Jacket: Silicone-coated steel monocoil Mixed UV-Visible & Visible-NIR Bifurcated Fibers

Product: QP400-2-UV-VIS Wavelength Range: 300nm – 1.1μm Fiber Core Size: 400 µm Length: 2 m Jacket: Silicone-coated steel monocoil UV-Visible Fiber