Get in touch for custom instrumentation solutions. Contact Us


Novo control, Technologies GmbH & Co. KG
Electrochemistry & AC Impedance

Novo control, Technologies GmbH & Co. KG


Dielectric Impedance Frequency : 3uHz -40MHz 1mohm to 300Tohm -160-400C +/-0.01deg Phase res -0.001deg

Available Variations

Check out different versions of this product

Novotherm-HT
Novotherm-HT

Turn key temperature control system including temperature controller, oven and 19" mounting rack. Temperature resolution: 0.1 °C Sample cell for high temperature tests under controlled atmosphere conditions like e.g. vacuum, inert gas, reactive gas, pH2O, etc included.

NOVOTHERM
NOVOTHERM

High quality turn key temperature control system Temperature range ambient … 400 °C Temperature ramps from 0.01 .. 20 °C/min

The Peltier-based Heat/Cool System PHECOS
The Peltier-based Heat/Cool System PHECOS

Operating principle: Dual-stage Peltier heat/cool system T range (PHECOS): −50 °C to 200 °C (for Tambient<25 °C)1 T range (PHECOS Lite): −35 °C to 150 °C (for Tambient<25 °C)

Novocool Cryosystem
Novocool Cryosystem

Economical temperature control system Temperature range −100 °C … +250 °C Temperature ramps from 0.1 .. 20 °C/min

Quatro Cryosystem
Quatro Cryosystem

High precision turn key temperature control system Temperature range −160 °C … 400 °C Temperature ramps from 0.01 °C/min .. 20 °C/min

Concept Turnkey Dielectric, Conductivity and Impedance Spectrometers with Temperature Control – Concept 50 and Concept 80
Concept Turnkey Dielectric, Conductivity and Impedance Spectrometers with Temperature Control – Concept 50 and Concept 80

Broadest frequency range : 3μH z . . . 3G H z Highest accuracy bases on high resolution ALPHA -A dielectric analyser and

Novocontrol Electrochemical Impedance System (NEISYS)
Novocontrol Electrochemical Impedance System (NEISYS)

Highly sophisticated potentiostat and galvanostat functions(±10 V, ±500 mA) Wide frequency range: 3 µHz … 100 MHz (100 kHz, 1 MHz, 10 MHz, 50 MHz optional) Base accuracy 0.1 % |Z|; 1 % U, I; 0.03° phase (0.03 % |Z|, 0.1 % U, I; 0.006° optional)

Broadband Dielectric Spectroscopy (BDS/DETA) –BDS50
Broadband Dielectric Spectroscopy (BDS/DETA) –BDS50

Frequency range: 3·10-5 .. 4.107 Hz Capacity range: 10-15 .. 1 F Impedance range: 0.01 – 1014 Ω

General Impedance Spectroscopy (IS)
General Impedance Spectroscopy (IS)

The Alpha-AT (3uHz – 40MHz) mainframe is the master unit of the Alpha-A modular measurement system for electric frequency domain measurements. For dielectric, conductivity and impedance spectroscopy the mainframe has to be operated in combination with one or more test interfaces.